Home Products Our company Contact us Anti-fake Center 笢恅
 
Our Company
Products
Our Commitments
News
Careers
Contact Us
Anti-fake Center
SPC Products
Power cable for power station
Type
Description
Application
The permissible
continuing temperature /⊥
Rated Voltage /V
Nominal cross-section /mm2
XEYH
EPDM insulation CSM jacket power cable Be suitable for fixed layout to power transmit and distribute electric energy in places like thermal power stations,nuclear,power plant,underground railway,petrochemical factory,channel,tall building,ect... 90
1000
2.5 ~ 400
XGEYH 6000
10000
ZR-XEYH EPDM insulation CSM jacket flame-retardant power cable Same as above,it has the anti-flaming performance. 1000
ZR-XGEYH 6000
10000
 
Type
Conductor construction
Max.OD of cable /mm
Max D.C Resistance of at 20⊥ ≒次/km
Min resistance of insulation at 20⊥ ≡M次/km
Nominal cross-section /mm
pcs /mm
XEYH
ZR-XEYH
0.6/1kv

1C
2.5
7/0.67
7.4
7.41
1100
4
7/0.85
8.0
4.61
920
6
7/1.04
8.6
3.08
790
10
7/1.35
9.9
1.83
740
16
7/1.70
11.0
1.15
620
25
7/2.14
12.7
0.727
580
35
7/2.52
15.0
0.524
500
50
19/1.78
17.3
0.387
490
70
19/2.14
19.1
0.268
420
95
19/2.52
21.4
0.193
400
120
37/2.03
23.1
0.153
360
150
37/2.25
26.1
0.124
360
185
37/2.52
28.4
0.0991
350
240
61/2.25
32.6
0.0754
340
300
61/2.52
35.4
0.0601
330
400
61/2.85
39.9
0.0470
310
 
Type
Conductor construction
Max.OD of cable /mm
Max D.C Resistance of at 20⊥ ≒次/km
Min resistance of insulation at 20⊥ ≡M次/km
Nominal cross-section /mm
pcs /mm
XEYH
ZR-XEYH
0.6/1kv

2C
2.5
7/0.67
12.1
7.41
1100
4
7/0.85
14.5
4.61
920
6
7/1.04
15.6
3.08
790
10
7/1.35
18.3
1.83
740
16
7/1.70
20.4
1.15
620
25
7/2.14
23.8
0.727
580
35
7/2.52
27.2
0.524
500
50
19/1.78
33.0
0.387
490
70
19/2.14
37.7
0.268
420
95
19/2.52
42.4
0.193
400
120
37/2.03
45.6
0.153
360
150
37/2.25
49.8
0.124
360
 
Type
Conductor construction
Max.OD of cable /mm
Max D.C Resistance of at 20⊥ ≒次/km
Min resistance of insulation at 20⊥ ≡M次/km
Nominal cross-section /mm
pcs /mm
XEYH
ZR-XEYH
0.6/1kv

3C
2.5
7/0.67
12.8
7.41
1100
4
7/0.85
15.0
4.61
920
6
7/1.04
16.4
3.08
790
10
7/1.35
19.3
1.83
740
16
7/1.70
21.5
1.15
620
25
7/2.14
26.4
0.727
580
35
7/2.52
28.9
0.524
500
50
19/1.78
35.0
0.387
490
70
19/2.14
40.0
0.268
420
95
19/2.52
45.0
0.193
400
120
37/2.03
49.6
0.153
360
150
37/2.25
53.9
0.124
360
 
Type
Conductor construction
Max.OD of cable /mm
Max D.C Resistance of at 20⊥ ≒次/km
Min resistance of insulation at 20⊥ ≡M次/km
Nominal cross-section /mm
pcs /mm
XEYH
ZR-XEYH
0.6/1kv

4C
2.5
7/0.67
14.9
7.41
1100
4
7/0.85
16.2
4.61
920
6
7/1.04
17.8
3.08
790
10
7/1.35
21.0
1.83
740
16
7/1.70
23.9
1.15
620
25
7/2.14
27.8
0.727
580
35
7/2.52
32.7
0.524
500
50
19/1.78
39.5
0.387
490
70
19/2.14
43.8
0.268
420
95
19/2.52
50.5
0.193
400
120
37/2.03
55.1
0.153
360
150
37/2.25
59.4
0.124
360
 
Type
Conductor construction
Max.OD of cable /mm
Max D.C Resistance of at 20⊥ ≒次/km
Min resistance of insulation at 20⊥ ≡M次/km
Nominal cross-section /mm
pcs /mm
XGEYH
ZR-XGEYH
0.6/6kv

1C
2.5
7/0.67
18.0
7.41
1100
4
7/0.85
19.5
4.61
920
6
7/1.04
20.2
3.08
790
10
7/1.35
21.5
1.83
740
16
7/1.70
24.0
1.15
620
25
7/2.14
26.2
0.727
580
35
7/2.52
27.4
0.524
500
50
19/1.78
28.7
0.387
490
70
19/2.14
31.6
0.268
420
95
19/2.52
33.5
0.193
400
120
37/2.03
35.1
0.153
360
150
37/2.25
37.8
0.124
360
185
37/2.52
39.6
0.0991
350
240
61/2.25
42.2
0.0754
340
300
61/2.52
44.7
0.0601
330
400
61/2.85
48.8
0.0470
310
 
 
Products | Our company | Contact us | Home   Copyright © 2010 Shanghai Power Cable&Wire Co.,LTD. All Rights Reserved